(0) articles
Votre panier de l'enquête est vide.
Close
Filters
Préférences
Rechercher

Healthcare Stress Analyzer for Mental State Monitoring

mobile workstation, easy to move
HMS096 is a quick and non-invasive medical device that adopts HRV theory to catch a tiny change of instantaneous cardiac cycle so that clinicians can estimate the activity and the balance of sympathetic and parasympathetic. Accordingly, the device is able to assess the patient’s body fatigue degree, anti-pressure ability, stress index, activity, and balance of the autonomic nervous system and other mental states.
Nous nous efforçons de maintenir notre approche de la tarification flexible - discutez avec nous pour obtenir une agréable surprise.
Discutez Maintenant

Convenient Operation: automatic test with the fingertip sensor only takes 5 minutes, user can get test report with dozens of parameters

Non-invasive Test Procedure: humanistic design, non-invasive and non-radioactive

Up to Standards: comply with HRV formulated by a committee jointly established by ESC & NASPE

Dual Domains Analysis: time and frequency quantification assessment, data objective, and accurate

Quantitative Analysis: quantification analysis of ANA system to observe its balance performance

Activity Analysis: The activity of sympathetic and parasympathetic nerves were analyzed to determine the degree of physical and mental pressure and fatigue.

Scientific and Accurate: Automatic generation of HRV comprehensive analysis report to assess the whole mental health condition

Host Weight: 16kg

Power: 60VA

Display: 19” LCD Monitor

Sample Frequency: 250Hz-500Hz

Baud Rate: up to 115200ps

PPG Sensor Wave Length: red light 660nm, infrared ray 905mm

Pulse Rate Measure Scale: 30bpm-250bpm±5%

Measure Time and Accuracy: 5min±3s

Measure Principle: HRV (heart rate variability) theory

Time Domain Analysis: Mean HR, SDNN, RMSSD, PSI, ApEn, SRD

Frequency Domain Analysis: TP, VLF, LF, HF, LF norm, HF norm, LF/HF ratio

 

Convenient Operation: automatic test with the fingertip sensor only takes 5 minutes, user can get test report with dozens of parameters

Non-invasive Test Procedure: humanistic design, non-invasive and non-radioactive

Up to Standards: comply with HRV formulated by a committee jointly established by ESC & NASPE

Dual Domains Analysis: time and frequency quantification assessment, data objective, and accurate

Quantitative Analysis: quantification analysis of ANA system to observe its balance performance

Activity Analysis: The activity of sympathetic and parasympathetic nerves were analyzed to determine the degree of physical and mental pressure and fatigue.

Scientific and Accurate: Automatic generation of HRV comprehensive analysis report to assess the whole mental health condition